Beckhoff Network & Wireless Cards Driver Download For Windows

Beckhoff Automation offers several gateway solutions to connect the following fieldbus systems to an EtherCAT network:

Beckhoff Network & Wireless Cards Driver Download For Windows 8.1

  • Serial interface RS422/RS485
  • AS-Interface (Master)
  • CANopen (Master and Slave)
  • CANopen (Master and Slave)
  • DeviceNet (Master)
  • DMX (Master and Slave)
  • Interbus (Slave)
  • IO-Link (Master)
  • Lightbus (Master)
  • PROFIBUS DP (Master or Slave)
  • PROFINET IO (Master or Slave)
  • PROFINET IRT (Slave*)
Beckhoff network & wireless cards driver download for windows 8.1

The diagnostic and configuration interface for Beckhoff IPCs accesses all parameters of an IPC by means of MDP (Modular Device Profile) and makes it possible for the user to display critical parameters and to link this information to executable actions. Uniform access to all parameters of a Beckhoff Industrial PC. The IXagent is an affordable and secure VPN solution that allows your Beckhoff Industrial PCs to be accessed from anywhere for remote service and maintenance purposes. This embedded software solution is compatible with Windows 10 devices from Beckhoff, allowing for a wide range of IPCs to be connected to IXON Cloud. A network adapter links the computer to the EtherCAT network for data exchange. 'Adapter Reference' option If this option is selected, an Ethernet adapter is selected via a reference. The 172 series is a Beckhoff standard. The subnet mask should be 255.255.0.0. Make sure you’re using a cross-over cable if a hub/switch/router is not being used.

* Product anncouncement

Serial interface RS422/RS485

The EL6021 serial interface enables the connection of devices with RS422 or RS485 interface. These devices communicate with the automation device via the coupler.

AS-Interface Master Terminal

The EL6201 AS-Interface master terminal enables the direct connection of AS-Interface slaves. The AS-Interface compliant interface supports digital and analog slaves, versions 2.0 and 2.1. The connected devices are supplied via the EL9520 AS-Interface potential feed terminal with filter.

CANopen Master/Slave Terminal

The EL6751 CANopen master terminal corresponds to the Beckhoff FC5101 CANopen PCI card. Due to the connection via EtherCAT, no PCI slots are required in the PC. Within an EtherCAT Terminal network, it enables the integration of any CANopen devices. The terminal can either be master or slave. In addition, general CAN messages can be sent or received – without having to bother with CAN frames in the applications program. The terminal has a powerful protocol implementation with many features:

  • All CANopen PDO communication types are supported: event driven, time driven (using an event timer), synchronous, polling.
  • synchronisation with the PC controller‘s task cycle
  • SYNC cycle with quartz precision for drive synchronisation, zero cumulative jitter
  • parameter communication (SDO) at start-up and when running
  • emergency message handling, guarding and heartbeat
  • powerful parameter and diagnostics interfaces
  • online bus load display
  • bus monitor functionality

The EL6751 is optionally also available as a slave version (EL6751-0010).

DeviceNet Master/Slave Terminal

The DeviceNet master terminal EL6752 corresponds to the Beckhoff FC5201 DeviceNet PCI card. Due to the connection via EtherCAT, no PCI slots are required in the PC. Within an EtherCAT Terminal network, the terminal enables the integration of any DeviceNet devices. The terminal can either be master or slave. The DeviceNet terminal has a powerful protocol implementation with many features:

  • All DeviceNet I/O modes are supported: polling, change of state, cyclic, strobed.
  • unconnected message manager (UCMM)
  • Offline Connection Set, Device Heartbeat Messages, Device Shutdown Messages
  • Auto Device Replacement (ADR)
  • powerful parameter and diagnostics interfaces
  • The error management for each bus user is freely configurable.

The EL6752 is optionally also available as a slave version (EL6752-0010).

DMX Master/Slave Terminal

The EL6851 EtherCAT Terminal is a DMX master terminal and enables connection of up to 32 devices without repeater. The DMX master terminal can send up to 512 bytes of data (this can be set via the terminal). At 250 kbit/s a maximum data rate of 44 kHz is therefore possible. The RS485 interface in the EL6851 is electrically isolated and guarantees high interference immunity.

Interbus Slave Terminal

The Interbus slave terminal EL6740-0010 facilitates data exchange between EtherCAT and Interbus. For both bus systems the terminal “mirrors” up to 64 bytes to the respective other system. The outputs are written to the inputs of the other bus with minimum delay. The terminal can use the Interbus protocol up to a baud rate of 2 Mbit. Due to the connection via EtherCAT, no PCI slots are required in the PC.

IO-Link Master Terminal

The IO-Link terminal enables connection of up to four IO-Link devices. A point-to-point connection is used between the terminal and the device. The terminal is parameterised via the master. 2-wire and 3-wire connections are supported. Additional 24 V and 0 V connection points can be realised via the EL918x potential distributor terminal.

Lightbus Master Terminal

Download

The EL6720 Lightbus master terminal enables the connection to Lightbus devices just as the Beckhoff FC2001 Lightbus PCI card. Due to the connection via EtherCAT, no PCI slots are required in the PC. The terminal controls the Lightbus protocol with all its features. Within an EtherCAT Terminal network, the EL6720 enables the integration of any Lightbus slaves. The terminal has a powerful protocol implementation with many features:

  • Cycle times up to 100 µs are possible
  • Process data communication can either be free running or synchronised
  • Powerful parameter and diagnostics interfaces (ADS)

Adapter - BECKHOFF


PROFIBUS DP Master/Slave Terminal

The PROFIBUS master terminal EL6731 corresponds to the Beckhoff FC3101 PROFIBUS PCI card. Due to the connection via EtherCAT, no PCI slots are required in the PC.
The terminal controls the PROFIBUS protocol with all its features. Within an EtherCAT Terminal network, it enables the integration of any PROFIBUS devices. Thanks to the PROFIBUS chip developed in-house, the terminals are equipped with the latest version of the PROFIBUS technology – including high-precision isochronous mode for axis control and expanded diagnostic options. These masters are the only ones that support different poll rates for the slaves. The PROFIBUS terminal has a powerful protocol implementation with many features:

  • cycle times from 200 µs are possible
  • PROFIBUS DP, PROFIBUS DP-V1, PROFIBUS DP-V2
  • master, slave and PROFIBUS monitor up to 12 Mbit/s
  • powerful parameter and diagnostics interfaces
  • The error management for each bus user is freely configurable.
  • It is possible to read the bus configuration and automatically assign the 'GSD' files.

The EL6731 is optionally also available as a slave version (EL6731-0010).

PROFINET IO Master/Slave Terminal

The EL6631 PROFINET IO controller (master) terminal supports the complete real-time function (RT) as well as extensive diagnostic possibilities. All services in accordance with Conformance Class B are supported. Up to 15 PROFINET IO devices can be projected on the EL6631.

The EL6631 is optionally also available as a slave version (EL6631-0010)

PROFINET IRT Slave Terminal

The EL6632 PROFINET IRT controller terminal offers the complete RT (real-time) or IRT (isochronous real-time) functionality and a wide range of diagnostic options. All services in accordance with Conformance Class C are supported. Depending on the cycle time, up to five PROFINET IRT or up to 15 PROFINET RT devices can be operated at the EL6632 in a line topology.

The maximum distance between two devices is 100 m. Protocols such as LLDP or SNMP can be used for network diagnostics.

Company

Beckhoff Automation GmbH & Co. KG

NoteInstall the Beckhoff TwinCAT automation software before installing the Beckhoff Ethernet card.
NoteAll screen shots of this documentation are made under Windows 2000.
Under Windows XP, the TwinCAT driver is installed in the same way.

After installation of the Beckhoff Ethernet card, Windows 2000, for example, comes up with the following message during start-up:

Follow the instructions of the Add Hardware Wizard.

Allow the assistant to search for a suitable driver.

The TwinCAT driver for real-time Ethernet is included with the Beckhoff TwinCAT automation.

Beckhoff network & wireless cards driver download for windows 8

If you have installed the Beckhoff TwinCAT automation software before installing the Beckhoff Ethernet card, the Add New Hardware Wizard will find the TwinCAT driver for real-time Ethernet in the driver database on the hard disk of your PC.

Operation of the TwinCAT drivers for real-time Ethernet requires no digital signature from Microsoft.
Beckhoff has thoroughly tested this driver in conjunction with the supported hardware and has verified compatibility with Windows 2000 and XP.
Click Yes to continue with the rest of the installation.

The TwinCAT driver for real-time Ethernet was installed successfully for an Ethernet port. Exit the installation with Finish.

If you are using a multi-channel Beckhoff Ethernet card, repeat the driver installation procedure for each additional channel:

Beckhoff Network & Wireless Cards Driver Download For Windows 7

Now you have to activate the TwinCAT Ethernet Protocol.

Resources

Example for the resources of an FC900x under Windows 2000.
(Control Panel/System/Hardware/Device Manager/Network adapters/TwinCAT Intel PCI-Ethernet adapter/Resources):

Beckhoff Network & Wireless Cards Driver Download For Windows 8